ISE SMART CONNECT KNX VAILLANT

ISE SMART CONNECT KNX VAILLANT

Together with the system controllers sensoCOMFORT or multiMATIC, the ISE SMART CONNECT KNX VAILLANT offers integration between eBUS and KNX.

With the ISE SMART CONNECT KNX VAILLANT, you can now also switch your heating system to "standby mode." This allows you to reduce the room temperature setpoint values in all rooms (if desired) and minimise heating.

Do you wish to be able to react to short-term changes in use quickly and easily (longer than usual periods of absence, visits by friends, parties etc.)?

With the ISE SMART CONNECT KNX VAILLANT, the times and setpoint values for heating and hot water can be changed temporarily or you can adjust ventilation control (especially through ventilation boosting) to your current requirements.

 

Informed in detail

Conveniently obtain key information directly from your heating system. Whether you are on the sofa or looking at the panel, you can read important data such as the hot water temperature, the circulation pump status or the minimum setpoint flow temperature for cooling mode quickly and clearly on your KNX visualisation display.

Informed in detail

Controlling heating as needed

Effective immediately, times and setpoint values for heating and hot water can be easily and quickly entered into the visualisation or any other operating device. This saves energy, as the system only works when it's needed.

Controlling heating as needed

Automatic ventilation

The ventilation system is started automatically after a meeting, e.g. after the last person has left the room. In this way, the following meeting can begin in a pleasant climate.

Automatic ventilation

A mode for long evenings

The night mode of the heating system can, for example, easily be set to a later point in time with the push of a button for the well being of guests at a later hour as well.

A mode for long evenings

+ POINTS

  • Save energy during longer absences

  • Integration of heating and ventilation in usage scenarios

  • Display of temperature and error status for up to eight heat generators

  • An overview of consumption and yield values

  • Integration into visualisations, e.g. Gira HomeServer

  • Recommended by Vaillant

Communication + Installation

The ISE SMART CONNECT KNX VAILLANT is simply connected to the eBUS of your KNX installation. Use the ETS to make configurations, carry out set up and Bob's your uncle.

ISE SMART CONNECT KNX VAILLANT


Features

  • Control of operation mode and temperature setpoint values for up to three heating zones

  • Control of operation mode and temperature setpoint value for hot water supply

  • Control of ventilation system operation mode

  • System information like service mode, error messages, date and time, outside temperature and system status

  • Heating circuit status values: Pump status, flow setpoint temperature, flow temperature, minimum flow setpoint temperature for cooling mode, heating curve for each heating circuit

  • Hot water status values: Circulation pump status, charging pump/3-way valve status, hot water temperature
  • Display of temperature and error status for up to eight heat generators

  • Yield values of solar systems and heatpumps

  • Consumption values for hot water supply and heating (electricity and gas)

  • Handover protocol from installer to system integrator

  • Simple integration into KNX (can be completely configured via ETS)

  • Easy-to-understand structure in the ETS5 thanks to channels

  • Extensions via firmware updates

 

Technical data (Gateway)

Voltage:

DC 24 V to 30 V

Power consumption:

1,2 W

IP communication:

Ethernet 10/100 BaseT

KNX communication:

KNX/TP, S-Mode

KNX medium:

TP1-256

Connections:

1x RJ45

1x USB

Connection and branching terminals for KNX and 24 V

Ambient temperature:

0 °C to +45 °C

Dimensions:

2 TE (REG plus)

 

Technical data (eBus Adapter)

Voltage:

Power supply via eBUS and USB

Power consumption:

0,1 W

Connections:

Mini USB B

eBUS via 2pol. terminal screw

Ambient temperature:

0 °C to +45 °C

Dimensions:

1 TE (REG)

Note:

  • Power supply via external DC 24 V
  • Set consists of eBUS adapter and gateway
  • For ETS5 or higher
  • Only for systems with the system controllers sensoCOMFORT or multiMATIC

Ordering info

Item number: S-0001-006

ISE SMART CONNECT KNX VAILLANT + eBUS-Adapter

Downloads

mime_icon
Installation Guide

 

assets/images/f/Flag_of_Germany-c4cc918f.svg- Icon assets/images/b/Flag_of_the_United_Kingdom-e7a35e4b.svg- Icon assets/images/1/Flag_of_the_Netherlands-7fa1a141.svg- Icon assets/images/1/Flag_of_Italy-1abde8b1.svg- Icon assets/images/5/Flag_of_Spain-def251d5.svg- Icon assets/images/4/Flag_of_France-a1939904.svg- Icon assets/images/d/Flag_of_Denmark-b94e987d.svg- Icon assets/images/0/Flag_of_Finland-45f17db0.svg- Icon assets/images/e/Flag_of_Sweden-776515be.svg- Icon assets/images/e/Flag_of_Norway-d7b401fe.svg- Icon assets/images/a/Flag_of_Portugal-bb6fb6ea.svg- Icon assets/images/c/Flag_of_Greece-a7c655cc.svg- Icon assets/images/f/Flag_of_the_Czech_Republic-4f6db24f.svg- Icon assets/images/c/Flag_of_Russia-388a87ec.svg- Icon assets/images/1/Flag_of_Slovenia-b8bf92f1.svg- Icon assets/images/d/Flag_of_Hungary-68366f2d.svg- Icon assets/images/7/Flag_of_Poland-73042d07.svg- Icon
mime_icon
Product Manual

Valid for Applications-Software Version 2.0 and Firmware Version 2.0

assets/images/f/Flag_of_Germany-c4cc918f.svg- Icon assets/images/b/Flag_of_the_United_Kingdom-e7a35e4b.svg- Icon assets/images/1/Flag_of_the_Netherlands-7fa1a141.svg- Icon assets/images/4/Flag_of_France-a1939904.svg- Icon
mime_icon
ISE SMART CONNECT KNX VAILLANT

ETS Product database entry Version 2.0

Download
mime_icon
Handover Protocol

Version from 13.05.2020

assets/images/f/Flag_of_Germany-c4cc918f.svg- Icon assets/images/b/Flag_of_the_United_Kingdom-e7a35e4b.svg- Icon assets/images/1/Flag_of_the_Netherlands-7fa1a141.svg- Icon assets/images/1/Flag_of_Italy-1abde8b1.svg- Icon assets/images/5/Flag_of_Spain-def251d5.svg- Icon assets/images/4/Flag_of_France-a1939904.svg- Icon assets/images/d/Flag_of_Denmark-b94e987d.svg- Icon assets/images/0/Flag_of_Finland-45f17db0.svg- Icon assets/images/e/Flag_of_Sweden-776515be.svg- Icon assets/images/e/Flag_of_Norway-d7b401fe.svg- Icon assets/images/a/Flag_of_Portugal-bb6fb6ea.svg- Icon assets/images/c/Flag_of_Greece-a7c655cc.svg- Icon assets/images/f/Flag_of_the_Czech_Republic-4f6db24f.svg- Icon assets/images/c/Flag_of_Russia-388a87ec.svg- Icon assets/images/1/Flag_of_Slovenia-b8bf92f1.svg- Icon assets/images/d/Flag_of_Hungary-68366f2d.svg- Icon assets/images/7/Flag_of_Poland-73042d07.svg- Icon
mime_icon
Installation Guide eBus Adapter

 

assets/images/f/Flag_of_Germany-c4cc918f.svg- Icon assets/images/b/Flag_of_the_United_Kingdom-e7a35e4b.svg- Icon assets/images/1/Flag_of_the_Netherlands-7fa1a141.svg- Icon assets/images/1/Flag_of_Italy-1abde8b1.svg- Icon assets/images/5/Flag_of_Spain-def251d5.svg- Icon assets/images/4/Flag_of_France-a1939904.svg- Icon assets/images/d/Flag_of_Denmark-b94e987d.svg- Icon assets/images/0/Flag_of_Finland-45f17db0.svg- Icon assets/images/e/Flag_of_Sweden-776515be.svg- Icon assets/images/e/Flag_of_Norway-d7b401fe.svg- Icon assets/images/a/Flag_of_Portugal-bb6fb6ea.svg- Icon assets/images/c/Flag_of_Greece-a7c655cc.svg- Icon assets/images/f/Flag_of_the_Czech_Republic-4f6db24f.svg- Icon assets/images/c/Flag_of_Russia-388a87ec.svg- Icon assets/images/1/Flag_of_Slovenia-b8bf92f1.svg- Icon assets/images/d/Flag_of_Hungary-68366f2d.svg- Icon assets/images/7/Flag_of_Poland-73042d07.svg- Icon
mime_icon
Firmware ISE SMART CONNECT KNX VAILLANT

Installation file Version 2.0.607

Download

Firmware version 2.0 for the ISE SMART CONNECT KNX VAILLANT available!

The ISE SMART CONNECT KNX VAILLANT is currently available in version 2.0.

Improvements in version 2.0:

  • Additional communication objects provide a great deal of key information.

  • New heating circuit status values: Pump status, flow setpoint temperature, flow temperature, minimum flow setpoint temperature for cooling mode

  • New hot water status values: Circulation pump status, charging pump/3-way valve status, hot water temperature

  • New functions can be used with both the sensoCOMFORT and multiMATIC controllers.
    Controllers sensoCOMFORT and multiMATIC

You can update existing gateways using the integrated function on the device website. The update is free of charge.
When updating the ISE SMART CONNECT KNX VAILLANT to the new firmware, updating the product database entry in the ETS is absolutely REQUIRED.